Electrical Operating & Discharge Rod

We are the suppliers of Electrical Operating & Discharge Rod that are made available in various specifications and types by us. The Discharge rod is an insulated pole that is used by electric utility members when engaged on live-line working on energized high - voltage electric power lines. The offered rod is designed as per the need and requirements of the industry. The offered rods are manufactured using quality material and are used for operation of drop-out fuses and cut-outs on transformers. The offered Electrical Operating & Discharge Rod is made available for efficient performance and use as per the need.

Electrical Discharge Rod Grounding Clamps

Discharge Rod Grounding Clamps

Fibre Glass Non Conductive Operating Discharge Rods

Specification

Material

Fiberglass

Discharge Range (Kv)

11 KV / 22 KV / 33 KV / 66 KV / 110 KV / 132 KV / 220 KV / 400 KV / 765 KV

Diameter (mm)

30

Weight (kg)

1.88

Brand

E-Safe

 

Grounding Clamps For Discharge Rod

Product details

Height

4 inches

Brand

Es afe

Material

Aluminium / Copper

Width

Up to 3 Inch

 

Discharge Rods

With the help of our mechanically advanced production unit, we are able to manufacture and supply our clients a wide assortment of Discharge Rods. The offered rods are demanded in electrical, automobile, chemical and other mechanical industry for discharging the excessive charge in least amount of time and at uniform surface area. These rods are properly designed and manufactured by utilizing finest quality materials at our well equipped production unit. Further, this Discharge Rods can be easily availed by our customers at economical price range.

Features:

  • Excellent quality
  • User friendly
  • Adorable design

Specifications:

  • High strength
  • High insulation
  • Made from pultruded fibre glass tubes
  • Telescopic multi section poles up to 6mtr
  • Infinite pole height adjustments
  • Aluminum Casted Discharge Head with Locking Mechanism
  • As per IS - 2071 (part 1) 1993, RA 1999 for power Frequency Voltage & lighting impulse voltage with standard test under dry & wet conditions.
  • Suitable for - 11kv, 33kv, 110kv, 220kv, 400kv.

Model No.: DR

Minimum Safe Working Distance

Minimum Voltage in KV Phase to Phase
Phase to Ground exposure
Phase to Phase exposure
11 kV
2'4" (0.72m)
2'7" (0.79m)
33 kV
2'7" (0.77m)
2'10" (0.86m)
110 kV
3'2" (0.95m)
4'3" (1.30m)
400 kV
11'3" (3.42m)
18'1" (5.51m)

Electrical Discharge Rod

As the flourishing industry, we are active in manufacturing and supplying the superior quality grade Electrical Discharge Rod. The offered discharge rod is designed by utilizing the finest grade materials at our well equipped production unit as per current market standards. The offered discharge rod is widely demanded in electrical, automobile, construction and other mechanical industry for setting electrical discharges such as galvanization process. Our clients can avail this Electrical Discharge Rod within the pre-defined time frame from us at affordable prices.

Features:

  • Rust proof coating
  • Excellent durability
  • Fine finish 

 

Specifications:

  • High strength
  • High insulation
  • Made from pultruded fibre glass tubes
  • Telescopic multi section poles up to 6mtr
  • Infinite pole height adjustments
  • Discharge Head made of Copper with spring tension mechanism.  
  • As per IS - 2071 (part 1) 1993, RA 1999 for power Frequency Voltage & lighting impulse voltage with standard test under dry & wet conditions.
  • Suitable for - 11kv, 33kv, 110kv, 220kv, 400kv.

Model : JH

J - Hook

Minimum Safe Working Distance

Minimum Voltage in KV Phase to Phase
Phase to Ground exposure
Phase to Phase exposure
11 kV
2'4" (0.72m)
2'7" (0.79m)
33 kV
2'7" (0.77m)
2'10" (0.86m)
110 kV
3'2" (0.95m)
4'3" (1.30m)
400 kV
11'3" (3.42m)
18'1" (5.51m)

Operating Cum Discharge Rod

We are efficiently manufacturing and supplying a wide range of superior quality Operating cum Discharge Rod. The offered discharge rod is designed in accordance with current market standards under the supervision of our experts by utilizing superior quality materials at well equipped production unit. This discharge rod is demanded in automobile, construction and other mechanical industries as a supporting or bridging component. Furthermore, clients can avail these Operating cum Discharge Rod from us at affordable price range.

Features:

  • Durable structure
  • Precisely designed
  • Corrosion resistant

Operating Cum Discharge Rod WITH UNIVERSAL HEAD  

  • High strength
  • High insulation
  • Made from pultruded fibre glass tubes
  • Telescopic multi section poles up to 6mtr
  • Infinite pole height adjustments
  • Aluminum casted Operating Cum Discharge Head
  • As per IS - 2071 (part 1) 1993, RA 1999 for power Frequency Voltage & lighting impulse voltage with standard test under dry & wet conditions.
  • Suitable for - 11kv, 33kv, 110kv, 220kv, 400kv.

Model No.: UH

Operating Cum Discharge Rod
Minimum Safe Working Distance

Minimum Voltage in KV Phase to Phase
Phase to Ground exposure
Phase to Phase exposure
11 kV
2'4" (0.72m)
2'7" (0.79m)
33 kV
2'7" (0.77m)
2'10" (0.86m)
110 kV
3'2" (0.95m)
4'3" (1.30m)
400 kV
11'3" (3.42m)
18'1" (5.51m)

Discharge Cum Operating Rod

Our association effectiveness is influential in manufacturing and supplying the excellent quality range of Discharge cum Operating Rod. The offered operating rod is demanded in construction fields as a fastening or supporting equipment. These operating rods are manufactured in harmony with current market standards by utilizing finest quality materials at our well equipped production unit. As per the varied demands of our valuable clients, we are offering this Discharge cum Operating Rod at best market price range.

Features:

  • Corrosion resistance
  • Superior strength
  • Hassle-free installation

Specifications:

  • High strength
  • High insulation
  • Made from pultruded fibre glass tubes
  • Telescopic multi section poles up to 6mtr
  • Infinite pole height adjustments
  • As per IS - 2071 (part 1) 1993, RA 1999 for power Frequency Voltage & lighting impulse voltage with standard test under dry & wet conditions.
  • Suitable for - 11kv, 33kv, 110kv, 220kv, 400kv.

Model No.: DH

Discharge Rod cum Operating Rod

Minimum Safe Working Distance

Minimum Voltage in KV Phase to Phase
Phase to Ground exposure
Phase to Phase exposure
11 kV
2'4" (0.72m)
2'7" (0.79m)
33 kV
2'7" (0.77m)
2'10" (0.86m)
110 kV
3'2" (0.95m)
4'3" (1.30m)
400 kV
11'3" (3.42m)
18'1" (5.51m)
X


Back to top